Specifications
|
i2500-18 and i2500-10
|
Range
|
Resolution
|
Accuracy
|
AC Current*
|
2500 A
|
0.1 A
|
3% ± 5 digits**
|
Frequency*
|
500 Hz
|
0.1 Hz
|
0.5% ± 5 digits
|
External magnetic field rejection (with cable >10 cm from the coupling)
|
40 dB
|
Inrush*
|
•
|
Safety rating
|
CAT III 1000 V, CAT IV 600 V
|
*When used with compatible Fluke meter. Accuracy stated includes probe and meter accuracy. ** For position accuracy at non-optimum positions, see Position sensitivity specifications table “A
|
Position sensitivity specifications
|
Distance from optimum
|
i2500-10
|
i2500-18
|
Additional iFlex error
|
A
|
0.5 in (12.7 mm)
|
1.4 in (35.6 mm)
|
± 0.5%
|
B
|
0.8 in (20.3 mm)
|
2.0 in (50.8 mm)
|
± 1.0%
|
C
|
1.4 in (35.6 mm)
|
2.5 in (63.5 mm)
|
± 2.0%
|
|
Measurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature.
|
|
|
|