Fluke 3000 FC Series Wireless Multimeter
* For all specifications: accuracy is specified for one year after calibration, at operating temperatures of 18 °C to 28 °C, with relative humidity at 0 % to 90 %. Accuracy specifications take the form of ± ([ % of Reading ] + [ Number of least significant digits ]).
Detailed Specifications
|
AC Voltage |
Range 1 |
Resolution |
Accuracy 2 3 4 |
45 Hz to 500 Hz |
500 Hz to 1 kHz |
600.0 mV |
0.1 mV |
1.0 % + 3 |
2.0 % + 3 |
6.000 V |
0.001 V |
60.00 V |
0.01 V |
600.0 V |
0.1 V |
1000 V |
1 V |
1 All AC voltage ranges are specified from 1 % of range to 100 % of range. 2 Crest factor of ≤ 3 at full scale up to 500 V, decreasing linearly to crest factor < 1.5 at 1000 V. 3 For non-sinusoidial waveforms, add ± (2 % of reading + 2 % full scale) typical, for crest factor up to 3. 4 Do not exceed 107 V-Hz. |
DC Voltage, Continuity, Resistance, Diode Test and Capacitance |
Function |
Range |
Resolution |
Accuracy |
mV |
600.0 mV |
0.1 mV |
0.09 % + 2 |
V |
6.000 V |
0.001 V |
0.09 % + 2 |
60.00 V |
0.01 V |
600.0 V |
0.1 V |
1000 V |
1 V |
0.15 % + 2 |
Ω |
600 Ω |
1 Ω |
Meter beeps at < 25 Ω, beeper detects opens or shorts of 250 μs or longer. |
Ω |
600.0 Ω |
0.1 Ω |
0.5 % + 2 |
6.000 kΩ |
0.001 kΩ |
0.5 % + 1 |
60.00 kΩ |
0.01 kΩ |
60.00 kΩ |
0.1 kΩ |
600.0 kΩ |
0.001 MΩ |
50.00 MΩ |
0.01 MΩ |
1.5 % + 3 |
Diode test |
2.000 V |
0.001 V |
1 % + 2 |
µF |
1000 nF |
1 nF |
1.2 % + 2 |
10.00 μF |
0.01 μF |
100.0 μF |
0.1 μF |
9999 μF1 |
1 μF |
10 % typical |
1 In the 9999 μF range for measurements to 1000 μF, the measurement accuracy is 1.2 % + 2. |
AC and DC Current |
Function |
Range 1 |
Resolution |
Accuracy |
mA AC (45 Hz to 1 kHz) |
60.00 mA |
0.01 mA |
1.5 % + 3 |
400.0 mA 3 |
0.1 mA |
mA DC 2 |
60.00 mA |
0.01 mA |
0.5 % + 3 |
400.0 mA 3 |
0.1 mA |
1 All AC current ranges are specified from 5 % of range to 100 % of range. 2 Input burden voltage (typical): 400 mA input 2 mV/mA. 3 400.0 mA accuracy specified up to 600 mA overload. |
Frequency |
Range |
Resolution |
Accuracy 1 |
99.99 Hz |
0.01 Hz |
0.1 % + 1 |
999.9 Hz |
0.1 Hz |
9.999 kHz |
0.001 kHz |
99.99 kHz |
0.01 kHz |
1 Frequency is specified up to 99.99 kHz in volts and up to 10 kHz in amps. |
Input Characteristics |
Function |
Overload protection |
Input impedance (nominal) |
Common mode rejection ratio (1 kΩ unbalance) |
Normal mode rejection |
|
1100 V RMS |
> 10 MΩ < 100 pF |
> 120 dB at DC, 50 Hz or 60 Hz |
> 60 dB at 50 Hz or 60 Hz |
|
1100 V RMS |
> 10 MΩ < 100 pF |
> 60 dB, DC to 60 Hz |
|
|
1100 V RMS |
> 10 MΩ < 100 pF |
> 120 dB at DC, 50 Hz or 60 Hz |
> 60 dB at 50 Hz or 60 Hz |
Open circuit test voltage |
Full scale voltage |
Typical short circuit current |
To 6 MΩ |
50 MΩ |
|
1100 V RMS |
< 2.7 V DC |
< 0.7 V DC |
< 0.9 V DC |
< 350 mA |
|
1100 V RMS |
< 2.7 V DC |
2.000 V DC |
< 1.1 mA |
mA Function |
Overload Protection |
Fused, 44/100 A, 1000 V FAST Fuse |
Overload |
600 mA overload for 2 minutes maximum, 10 minutes rest minimum |
MIN/MAX Recording Accuracy |
DC functions |
The specified accuracy of the measurement function ± 12 counts for changes > 350 mS in duration. |
AC functions |
The specified accuracy of the measurement function ± 40 counts for changes > 900 mS in duration. |
General Specifications
|
Maximum voltage between any terminal and earth ground |
1000 V DC or AC RMS |
Ω fuse protection from A inputs |
0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only |
Display (LCD) |
Update rate: 4/sec Volts, amps, ohms: 6000 counts Frequency: 10,000 counts Capacitance: 1,000 counts |
Battery type |
Three AA Alkaline batteries, NEDA 15A IEC LR6 |
Battery life |
250 hours minimum |
RF communications |
2.4 GHZ ISM Band |
RF communication range |
Open air, unobstructed: Up to 20m Obstructed, sheetrock wall: Up to 6.5m Obstructed, concrete wall, or steel electrical enclosure: Up to 3.5m |
Temperature |
Operating: -10 °C to 50 °C Storage: -40 °C to 60 °C |
Temperature coefficient |
0.1 X (specified accuracy) /°C (<18 °C or >28 °C) |
Relative humidity |
0 % to 90 % (0 °C to 35 °C) 0 % to 75 % (35 °C to 40 °C) 0 % to 45 % (40 °C to 50 °C) |
Altitude |
Operating: 2,000 m Storage: 12,000 m |
Electromagnetic compatibility EMI, RFI, EMC, RF |
EN 61326-1:2006, EN 61326-2-2:2006 ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489 V1.8.1:2008, FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249 FCCID : FCC: T68-FDMMBLE IC: 6627A-FDMMBLE |
Safety compliance |
ANSI/ISA 61010-1 / (82.02.01): 3rd edition CAN/CSA-C22.2 No 61010-1-12: 3rd edition UL 61010-1: 3rd edition IEC/EN 61010-1:2010 |
Certifications |
CSA, FCC, CE |
Ingress Protection (IP) rating |
IP54 |
Pollution degree |
2 |
Size (H x W x L) |
4.75 cm x 9.3 cm x 20.7 cm (1.87 in x 3.68 in x 8.14 in) |
Weight |
340 g (12 oz) |
Warranty |
Three years |
Note: Not compatible with Fluke CNX test tools
Fluke v3000 FC Wireless AC Voltage Module
Accuracy is specified as ± ([% of reading] + [number of least significant digits]). All ranges are autoranging. Accuracy is specified from 5 % to 100 % of the range obtained by autoranging, from 18 °C to 28 °C.
Specifications
|
Range1 |
Resolution |
Accuracy2,3,4 |
45 Hz to 500 Hz |
500 Hz to 1 kHz |
6.000 V |
0.001 V |
1.0 % + 3 |
2.0 % + 3 |
60.00 V |
0.01 V |
600.0 V |
0.1 V |
1000 V |
1 V |
1 All ac voltage ranges are specified from 1 % of range to 100 % of range. 2 Crest factor of ≤ 3 at full scale up to 500 V, decreasing linearly to crest factor ≤ 1.5 at 1000 V. 3 For non-sinusoidial waveforms, add –(2 % of reading + 2 % full scale) typical, for crest factor up to 3. 4 Do not exceed 106 V-Hz. |
General Specifications
|
LCD w/backlight |
3½ digits, 6000 counts, updates 4/sec |
Battery type |
2 AA, NEDA 15 A, IEC LR6 |
Battery life |
400 Hours |
Memory |
Record up to 65000 readings |
RF communications |
2.4 GHZ ISM Band |
RF communication range |
Open air, unobstructed: Up to 20 m Obstructed, sheetrock wall: Up to 6.5 m Obstructed, concrete wall or steel electrical enclosure: Up to 3.5 m |
Operating temperature |
-10 °C to +50 °C |
Storage temperature |
-40 °C to +60 °C |
Temperature coefficient |
0.1 X (specified accuracy)/°C (< 18 °C or > 28 °C) |
Operating humidity |
90 % at 35 °C, 45 % at 40 °C, 45 % at 50 °C |
Altitude |
Operating: 2,000 m Storage: 12,000 m |
EMC |
EN 61326-1:2006 |
Safety compliance |
ANSI/ISA 61010-1 / (82.02.01): 3rd edition CAN/CSA-C22.2 No 61010-1-12: 3rd edition UL 61010-1: 3rd edition IEC/EN 61010-1:2010 |
Safety rating |
CAT IV 600 V, CAT III 1000 V |
Certifications |
CSA, CE, FCC: T68-FBLE IC: 6627A-FBLE |
Ingress Protection (IP) rating |
IP42 |
Pollution Degree |
2 |
Size (HxWxD) |
16.5 cm x 6.35 cm x 1.4 cm (6.5 in x 2.5 in x 1.4 in) |
Weight |
.22 kg (8 oz) |
Warranty |
Three years |
Note: Not compatible with Fluke CNX test tools
Fluke v3001 FC Wireless DC Voltage Module
Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, with relative humidity at 0 % to 90 %. Accuracy specifications take the form of ±([ % of Reading ] + [ Number of least significant digits ]).All ranges are autoranging. Accuracy is specified from the range obtained by autoranging, from 18 °C to 28 °C.
Voltage Specifications |
Function |
Range |
Resolution |
Accuracy |
mV DC |
600.0 mV |
0.1 mV |
0.09 % + 3 |
V DC |
6.000 V |
0.001 V |
0.09 % + 3 |
60.00 V |
0.01 V |
600.0 V |
0.1 V |
1000 V |
1 V |
0.15 % + 2 |
General Specifications |
LCD w/backlight |
3 ½ digits, 6000 counts, 4/sec update rate |
Battery type |
2 AA Alkaline batteries, NEDA 15A, IEC LR6 |
Log rate/interval |
Adjustable by PC from 1 sec to 1 hr, default 1 min |
Battery life |
400 hours minimum |
Memory |
Record up to 65,000 readings |
RF communications |
2.4 GHz ISM Band |
RF communication range |
Open air, unobstructed: Up to 20 m Obstructed, sheetrock wall: Up to 6.5 m Obstructed, concrete wall or steel electrical enclosure: Up to 3.5 m |
Operating temperature |
-10 °C to +50 °C |
Storage temperature |
-40 °C to +60 °C |
Temperature coefficient |
0.1 X (specified accuracy)/°C (< 18 °C or > 28 °C) |
Relative humidity |
0 % to 90 % (0 °C to 35 °C), 0 % to 75 % (35 °C to 40 °C), 0 % to 45 % (40 °C to 50 °C) |
EMC |
IEC 61236-1, Portable |
Safety compliance |
IEC 61010-1, 600 V CAT IV / 1000 V CAT III, 3rd edition, Pollution Degree 2 |
Certifications |
CSA, CE, FCC: T68-FBLE IC: 6627A-FBLE |
Ingress Protection (IP) rating |
IP42 |
Size (HxWxD) |
160 mm x 66 mm x 38 mm (6.3 in x 2.6 in x 1.5 in) |
Weight |
0.255 kg (9 oz) |
Warranty |
Three years |
Note: Not compatible with Fluke CNX test tools
Fluke a3001 FC Wireless iFlex® AC Current Module
Specifications
|
Range |
0.5 A to 2500 A AC |
Resolution |
0.1 A |
Accuracy |
3 % ± 5 digits (5 Hz to 500 Hz) |
Crest factor (50 Hz/60 Hz) |
3.0 at 1100 A, 2.5 at 1400 A, 1.42 at 2500 A, add 2 % for C.F. > 2 |
LCD w/backlight |
3½ digits |
Log rate/interval |
1 sec minimum/adjustable by PC or front panel |
Battery type |
2 AA, NEDA 15 A, IEC LR6 |
Battery life |
400 hours |
Memory |
Record up to 65,000 readings |
RF communications |
2.4 GHZ ISM Band |
RF communication range |
Open air, unobstructed: Up to 20 m Obstructed, sheetrock wall: Up to 6.5 m Obstructed, concrete wall or steel electrical enclosure: Up to 3.5 m |
Operating temperature |
-10 °C to +50 °C |
Storage temperature |
-40 °C to +60 °C |
Temperature coefficient |
Add 0.1 X (specified accuracy)/ °C (<18 °C or >28 °C) |
Operating humidity |
90 % at 35 °C, 75 % at 40 °C, 45 % at 50 °C |
Altitude |
Operating: 2,000 m Storage: 12,000 m |
EMC |
EN 61326-1:2006 |
Safety compliance |
IEC 61010-1, 600 V CAT IV/1000 V CAT III, 3rd edition |
Safety rating |
CAT IV 600 V, CAT III 1000 V |
Certifications |
CSA, CE, FCC: T68-FBLE IC: 6627A-FBLE |
Ingress Protection (IP) rating |
IP42 |
Pollution degree |
2 |
Jaw opening |
25.4 cm (10 in) coil |
Size (HxWxD) |
16.5 cm x 6.35 cm x 1.4 cm (6.5 in x 2.5 in x 1.4 in) |
Weight |
.22 kg (8 oz) |
Warranty |
Three years |
Note: Not compatible with Fluke CNX test tools